Automatic glycosylated hemoglobin analyzer VZN GHA 200
- The cost of equipment includes commissioning and personnel training.
- The warranty is 24 months
-
Description
-
Specifications
-
Exchange and return
-
Payment and delivery
The glycosylated hemoglobin analyzer is used to detect the chemical binding of hemoglobin (found in erythrocytes) with glucose. The analysis is utilized to determine the average glucose content in the blood over the last 2-3 months. The system is designed for the quantitative measurement of glycosylated hemoglobin in human blood. This indicator is very reliable for diagnosing treatment control and diabetes mellitus. Due to its ease of use, high accuracy of results, and cost-effectiveness, it is indispensable in medical clinics and laboratories, as well as in diabetic specialty institutions.
Precise separation by 4-gradient elution The new 4-gradient elution for HbA1C can accurately separate glycated hemoglobin by 4-gradient elution of the appropriate concentration of reagent targeting HbA1C, instead of the conventional elution process that is created by a mixture of high and low concentrations.
High performance liquid chromatography column The high-performance liquid chromatography column, made of imported resin, has a volume of 9 mm x 45 mm and a weight of 2.5 g, which is 15-20 times larger than a conventional microchromatography column. The high-performance 300-test chromatography column ensures accurate test results.
Built-in high-sensitivity 415 nm LED photometer The high-sensitivity 415nm LED integrated photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, microcuvette, and high sensitivity. It can accurately record the analysis curve.
Technical Specifications:
|
Testing Method |
Low-Pressure Ion Exchange Liquid Chromatography |
|
Tested Object |
Glycated Hemoglobin HbA1c |
|
Testing Range |
3%-18% |
|
Testing Parameters |
Precision (CV) ≤3%, Precision (V) ≤1.50% |
|
Testing Time |
4 minutes (reporting), complete processing 6 minutes (including column cleaning and recovery time) |
|
Sample Type |
Venous blood (EDTA anticoagulant), peripheral finger blood |
|
Sample Volume |
5 µL of whole blood for each sample |
Functional Parameters
|
Photometer |
415 nm LED Integrated Flow Colorimeter |
|
Sampling Mode |
Fully automatic 20-position rotating sample table |
|
Testing Mode |
Automatic batch test, one test for emergencies |
|
Calibration |
Additional choice of 2 or 4-point calibration, additional choice of manual or automated calibration, equipped with 2 groups of high and low-level calibrators |
|
Thermostatic Control |
Column and reagent thermostatic control: 25 ±0.5°C |
|
Reagent Compliance |
One part of the column and consumables for reagents/300 test samples |
|
Reagent Distribution |
Each standard package includes eluent A, B, C, D, calibrator, hemolytic agent, pump tube |
Output Parameters
|
Display |
Graphic display showing the testing curve in real-time |
|
Printer |
Thermal printer 58 nm, printing test curve and report |
|
Output Report |
IFCC concentration value, NGSP area percentage, ADAG average glucose level |
|
Data Storage |
1000 test reports (including test curves) |
Operating Parameters
|
Power Source |
AC220V±22V, 50HZ, 65VA |
|
Size |
408x390x230 mm |
|
Weight |
8 kg |
|
Operating Environment |
Temperature: 12-30°C, relative humidity: ≤85% |
|
Testing Method |
Low-Pressure Ion Exchange Liquid Chromatography |
|
Tested Object |
Glycated Hemoglobin HbA1c |
|
Testing Range |
3%-18% |
|
Testing Parameters |
Precision (CV) ≤3%, Precision (V) ≤1.50% |
|
Testing Time |
4 minutes (reporting), complete processing 6 minutes (including column cleaning and recovery time) |
|
Sample Type |
Venous blood (EDTA anticoagulant), peripheral finger blood |
|
Sample Volume |
5 µL of whole blood for each sample |
Functional Parameters
|
Photometer |
415 nm LED Integrated Flow Colorimeter |
|
Sampling Mode |
Fully automatic 20-position rotating sample table |
|
Testing Mode |
Automatic batch test, one test for emergencies |
|
Calibration |
Additional choice of 2 or 4-point calibration, additional choice of manual or automated calibration, equipped with 2 groups of high and low-level calibrators |
|
Thermostatic Control |
Column and reagent thermostatic control: 25 ±0.5°C |
|
Reagent Compliance |
One part of the column and consumables for reagents/300 test samples |
|
Reagent Distribution |
Each standard package includes eluent A, B, C, D, calibrator, hemolytic agent, pump tube |
Output Parameters
|
Display |
Graphic display showing the testing curve in real-time |
|
Printer |
Thermal printer 58 nm, printing test curve and report |
|
Output Report |
IFCC concentration value, NGSP area percentage, ADAG average glucose level |
|
Data Storage |
1000 test reports (including test curves) |
Operating Parameters
|
Power Source |
AC220V±22V, 50HZ, 65VA |
|
Size |
408x390x230 mm |
|
Weight |
8 kg |
|
Operating Environment |
Temperature: 12-30°C, relative humidity: ≤85% |
| Condition | New |
Please note that the possibility of exchange or return is provided for "non-conforming quality" goods. This means that if the product breaks down during the warranty period due to manufacturing defects, you have the right to replace or return it.
Regarding goods of proper quality (those that function and have no faults), exchange or return is possible only if the product has not been used and has no visible signs of use, such as scratches, chips, or abrasions. Moreover, it is necessary to keep the complete set, integrity of the packaging and all its components, as well as the presence of factory markings and labels.
If you have any questions regarding the return of goods, please contact us in any of the following ways:
In accordance with Article 9 of the Law of Ukraine "On Consumer Rights Protection", to return or exchange goods, the following return conditions must be adhered to:
- The return of goods of proper quality can be made within two weeks from the date of receipt;
- The presence of a fiscal receipt;
- The goods are not on the list of those that are not subject to exchange and return;
- The product has not been used and has been kept in the condition in which it was purchased, except for consumables, which are not subject to exchange and return;
- Return shipping of goods is at the expense of the consumer;
- The return of goods of proper quality can be made within two weeks from the date of receipt;
- Refund of money takes place within 30 working days to the client's bank account;
- cashless payment (FOP or VAT);
- cash.
- pickup from a warehouse in Kyiv;
- delivery by Nova Poshta and other transport companies;