SURTRON® TOUCH HP, the new generation of electrosurgery. Performance, ease of use, design, and reliability are the key advantages of the new SURTRON TOUCH HP device. The radiofrequency generator is used for microsurgery and precise surgery in monopolar and bipolar modes. The initial setup of SURTRON TOUCH HP and adjustment of settings during surgery are easily done using the large touchscreen. The simplicity of SURTRON TOUCH HP allows for use without prior training.
Over 35 years of experience in electrosurgery and continuous research have helped create SURTRON TOUCH HP. The new generation features technological and functional characteristics:
- Simultaneous activation of monopolar and bipolar modes;
- Simultaneous activation of two monopolar instruments;
- Simultaneous activation of two bipolar instruments;
- Built-in argon flow control module;
- Power regulation based on impedance;
- Activation by footswitch and/or buttons;
- Patient/neutral electrode contact control;
- TUR resection in aqueous environment;
- BLEND resection in moist environment;
- VESSEL SEALING for vessel occlusion up to 7 mm;
- Performing minimally invasive surgeries;
- Monopolar/bipolar modes;
- Automatic start/stop in bipolar mode;
- Volume control.
SURTRON TOUCH HP has an intuitive operating interface. Horizontal alignment with the monitor, RGB light indicators, and connectors provide a simple and understandable working environment. Tool connectors are located on the side, allowing for monitoring of important information without interference, such as accessory cable connections. The large 9-inch touchscreen has a flat smooth design on the front panel, providing faster and more efficient cleaning of the operating room. SURTRON TOUCH HP allows for highly professional operations due to its intuitive and safe design. Neutral electrode connection is constantly monitored. When using a separate neutral electrode, patient contact with the electrode is constantly monitored. The ability to change modes and adjust power using buttons on the handle allows for performing the operation without distraction to set up the device.
Resection
SURTRON TOUCH HP has several monopolar resection modes. In addition to PURE resection, there is a high-impedance resection mode called ENHANCED. The resection mode for better results in a moist environment is BLEND. The new DUO mode allows for simultaneous use of two instruments in standard resection mode. In the bipolar area, in addition to the standard PURE resection mode, there is a mode that allows for resection without energy gates in the TUR aqueous environment.
|
Monopolar |
Pure 400 W - 300 Ω
|
|
Enchanced 250 W - 300 Ω
|
|
|
Blend 250 W - 300 Ω
|
|
|
Duo 200 W + 200 W 300 Ω |
|
|
Bipolar |
Pure 150 W - 50 Ω |
|
Tur 200 W - 50 Ω |
Coagulation
Monopolar coagulation has the following operating modes: surface coagulation FORCED and deep coagulation SOFT, using low voltage. FULGURATION and SPRAY modes allow for quick coagulation without skin contact, thanks to high voltage. The new DUO mode allows for surface coagulation with two instruments simultaneously. In the bipolar area, two modes, standard BIPOLAR and vessel occlusion up to 7 mm SEALING, complete the list of SURTRON TOUCH HP device functions.
|
Monopolar |
Forced 150 W - 300 Ω |
|
Soft 150 W - 200 Ω |
|
|
Fulguration 100 W - 500 Ω |
|
|
Spray 100 W - 1000 Ω |
|
|
Duo 50 W + 50 W 500 Ω |
|
|
Bipolar |
Bipolar 120 W - 50 Ω |
|
Sealing 200 W - 50 Ω |
Accessories:
- Disposable handle with buttons (5 pcs);
- Reusable handle with buttons;
- Knife electrode 7 cm (3 pcs);
- Knife electrode 16 cm (3 pcs);
- Needle electrode 7 cm (3 pcs);
- Ball electrode 6 cm (3 pcs);
- Neutral electrode cable;
- Disposable split neutral electrode (5 pcs);
- Sponge for electrode cleaning;
- Double waterproof footswitch (2 pcs);
- Power cable 5 m.
Monitoring:
- Patient circuit monitoring;
- Output power monitoring;
- Self-test;
- RF energy leakage monitoring;
- Power supply voltage fluctuations compensation.
Safety:
- EN60601-1;
- EN60601-1-2;
- EN60601-2-2;
- Electrical classification: I CF;
- MDD 93/42/EC Class: II b.
Technical Specifications:
|
Codice prodotto |
10400.T902 |
|
Max. output power monop. resection PURE |
400 W - 300 Ω |
|
Max. output power monop. resection ENHANCED |
250 W - 300 Ω |
|
Max. output power monop. resection with coag. BLEND |
250 W - 300 Ω |
|
Max. output power monop. coag. FORCED |
150 W - 300 Ω |
|
Max. output power monop. coag. SOFT |
150 W - 200 Ω |
|
Max. output power monop. coag. FULGURATION |
100 W - 500 Ω |
|
Max. output power monop. coag. SPRAY |
100 W - 1000 Ω |
|
Max. output power monop. coag. SPRAY ARGON |
100 W - 1000 Ω |
|
Max. output power bipol. resection PURE |
120 W - 50 Ω |
|
Max. output power bipol. resection with coag. TUR |
200 W - 50 Ω |
|
Max. output power bipol. coag. BIPOLAR |
120 W - 50 Ω |
|
Max. output power bipol. coag. SEALING |
200 W - 50 Ω |
|
Operating frequency |
360 kHz |
|
Patient circuit |
F |
|
Argon flow rate setting |
0.2 - 10 l/min |
|
Max. argon inlet pressure |
3.0 bar |
|
Power supply voltage |
100 - 240 V |
|
Power supply frequency |
50 / 60 Hz |
|
Power consumption |
1000 VA |
|
Size WxHxD |
470x220x460 mm |
|
Weight |
13.5 kg |
|
Max. output power monop. resection PURE |
400 W - 300 Ω |
|
Max. output power monop. resection ENHANCED |
250 W - 300 Ω |
|
Max. output power monop. resection with coag. BLEND |
250 W - 300 Ω |
|
Max. output power monop. coag. FORCED |
150 W - 300 Ω |
|
Max. output power monop. coag. SOFT |
150 W - 200 Ω |
|
Max. output power monop. coag. FULGURATION |
100 W - 500 Ω |
|
Max. output power monop. coag. SPRAY |
100 W - 1000 Ω |
|
Max. output power monop. coag. SPRAY ARGON |
100 W - 1000 Ω |
|
Max. output power bipol. resection PURE |
120 W - 50 Ω |
|
Max. output power bipol. resection with coag. TUR |
200 W - 50 Ω |
|
Max. output power bipol. coag. BIPOLAR |
120 W - 50 Ω |
|
Max. output power bipol. coag. SEALING |
200 W - 50 Ω |
|
Operating frequency |
360 kHz |
|
Patient circuit |
F |
|
Argon flow rate setting |
0.2 - 10 l/min |
|
Max. argon inlet pressure |
3.0 bar |
|
Power supply voltage |
100 - 240 V |
|
Power supply frequency |
50 / 60 Hz |
|
Power consumption |
1000 VA |
|
Size WxHxD |
470x220x460 mm |
|
Weight |
13.5 kg |
Please note that the possibility of exchange or return is provided for "non-conforming quality" goods. This means that if the product breaks down during the warranty period due to manufacturing defects, you have the right to replace or return it.
Regarding goods of proper quality (those that function and have no faults), exchange or return is possible only if the product has not been used and has no visible signs of use, such as scratches, chips, or abrasions. Moreover, it is necessary to keep the complete set, integrity of the packaging and all its components, as well as the presence of factory markings and labels.
If you have any questions regarding the return of goods, please contact us in any of the following ways:
In accordance with Article 9 of the Law of Ukraine "On Consumer Rights Protection", to return or exchange goods, the following return conditions must be adhered to:
- The return of goods of proper quality can be made within two weeks from the date of receipt;
- The presence of a fiscal receipt;
- The goods are not on the list of those that are not subject to exchange and return;
- The product has not been used and has been kept in the condition in which it was purchased, except for consumables, which are not subject to exchange and return;
- Return shipping of goods is at the expense of the consumer;
- The return of goods of proper quality can be made within two weeks from the date of receipt;
- Refund of money takes place within 30 working days to the client's bank account;
- cashless payment (FOP or VAT);
- cash.
- pickup from a warehouse in Kyiv;
- delivery by Nova Poshta and other transport companies;